Air Vertical Receivers

UON offers a range of vertical air receivers up to 25 m3 that are specifically designed for use in industrial compressed air systems.

Benefits

  • Designed, manufactured and tested in accordance with Australian Standard AS 1210.
  • Manufacturer's data report provided in accordance with Australian Standard AS 4458
  • OH&S Registered Design approved for workplace use in all Australian States and Territories
  • Industry preferred socket sizes and placement reinforced vessel support attachments
  • External surfaces are abrasive blast cleaned, primed, finish coated in two pack polyurethane paint and then oven dried
  • Blue external colour (similar to Dulux® Process Blue) indicates compressed air content in accordance with Australian Standard AS 1345
  • Individually packed in a horizontal position inside a full timber crate with plastic bag cover

Features

  • Design temperature range: 0°C to 100°C
  • Design fluid contents: Air
  • All socket threads are BSP

air-filters

 

Range And Technical Specifications

Model CodeVOLUME (Litres)DESIGN PRESSURE (kPa)WEIGHT (kg)
FS V150LP 150 1,320 72
FS V330LP 330 1,210 125
FS V530LP 530 1,280 200
FS V820LP 820 1,154 300
FS V1240LP 1,240 1,035 430
FS V2400-1080 2,400 157 858
FS V5000-1145 5,000 166 1,657

Dimensions

A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H (mm)J (mm)K (inch)L (inch)M (inch)N (mm)P (inch)Q (mm)R (mm)
390 214 1,700 750 450 375 250 622 1,200 1/2 3/4 1.5 150 1/2 14 388
490 250 2,210 780 900 405 250 825 1,650 1/2 3/4 1.5 150 1/2 14 505
640 348 2,140 820 750 445 250 750 1,500 1/2 3/4 2 150 1/2 14 667
780 360 2,215 875 720 500 250 735 1,470 3/4 3/4 2 150 1/2 18 791
975 500 2,213 889 690 514 250 720 1,440 3/4 1 2 150 3/4 18 967